Cardinal *Now Available!*
Triangle Tube is proud to introduce its latest product innovation, the Cardinal. This stainless steel indirect water heater is available in several sizes ranging from 30 to 120 gallons, providing ample hot water. Additional features include a stainless steel coil tank, 1” boiler connections and top DHW connections.

Warranty Info
At Triangle Tube, our goal is to deliver the highest quality products to customers throughout North America. As part of our continued commitment, we offer a Peace of Mind Industry-Leading Three Point (Good / Better / Best) Warranty Program. This program offers up to a Lifetime tank assembly warranty, 6-year components and parts, and coverage with a 3-year labor allowance.
Features and Benefits
-
Stainless Steel Coil Tank
-
1″ Boiler Connections
-
Top DHW Connections 3/4″ (30-60) 1″ (80-120)
-
Factory Included: T&P Valve
-
Factory Included: 1/4 Turn Drain Valve
-
Therm-O-Well
-
AHRI Certified Rating and Listed
-
Sizes: 30, 40, 50, 60, 80, 100, 120 Gallons
-
Peace of Mind Warranty
Product/Marketing Literature
Installation/User Manuals
Submittals
Cardinal
Triangle Tube is proud to introduce its latest product innovation, the Cardinal.
Product Comparison
Specifications | Cardinal 30 | Cardinal 40 | Cardinal 50 | Cardinal 60 | Cardinal 80 | Cardinal 100 | Cardinal 120* |
---|---|---|---|---|---|---|---|
Diameter | 22.25″ | 22.25″ | 22.25″ | 22.25″ | 26.50″ | 26.50″ | 32″ |
Height | 40.50″ | 50.50″ | 56.25″ | 64″ | 61″ | 73″ | 63.50″ |
Boiler/Supply Return (MNPT) | 1″ | 1″ | 1″ | 1″ | 1″ | 1″ | 1″ |
Domestic Inlet/Outlet (MNPT) | 3/4″ | 3/4″ | 3/4″ | 3/4″ | 1″ | 1″ | 1″ |
Auxiliary DHW Connection (MNPT) | 3/4″ | 3/4″ | 3/4″ | 3/4″ | 1″ | 1″ | 1″ |
T&P Connection (FNPT) | 3/4″ | 3/4″ | 3/4″ | 3/4″ | 3/4″ | 3/4″ | 3/4″ | Drain Connection (FNPT) | 1/2″ | 1/2″ | 1/2″ | 1/2″ | 1/2″ | 1/2″ | 1/2″ | Coil Capacity (Gal.) | 1.3 | 1.3 | 1.6 | 1.6 | 2 | 2 | 3 | DHW Water Capacity (Gal.) | 31 | 40 | 46.3 | 53.2 | 78.9 | 96.4 | 119 | Standby Loss, F/h | 1 | 0.7 | 0.8 | 0.6 | 0.5 | 0.5 | 0.3 | Heating Surface (Sq. Ft.) | 8.50 | 8.50 | 12 | 12 | 16 | 16 | 21.50 | Weight – Empty (Lbs.) | 62 | 73 | 84 | 92 | 130 | 134 | 174 | Weight – Shipping (Lbs.) | 76 | 88 | 100 | 110 | 156 | 165 | 208 | Boiler Output (Btu/Hr) | 120,000 | 122,000 | 154,000 | 156,000 | 192,000 | 192,000 | 253,000 | First Draw (Gal/Hr) | 25 | 34 | 39 | 47 | 70 | 89 | 101 | 1st Hour Rating (Gal/Hr) | 214 | 228 | 281 | 293 | 372 | 391 | 486 | Continuos Flow (Gal/Hr) | 189 | 194 | 242 | 247 | 302 | 298 | 385 | Pump Requirements | 14 GPM / 2.3′ | 14 GPM / 2.3′ | 14 GPM / 3.4′ | 14 GPM / 3.4′ | 14 GPM / 5.3′ | 14 GPM / 5.3′ | 14 GPM / 6.7′ |
*Approval Pending |